Chain Link Fence Installation Ground Level with Concrete Foundations and Wall Mount Installation Methods

Author:Yudemeiwiremesh 2026-06-30 10:00:54 57 0 0

Chain Link Fence Installation Ground Level with Concrete Foundations and Wall Mount Installation Methods

Security chain link fence material supply and installation project in Netherlands, including replacement and new installation. The project is divided into two main sections. First Section – 1200 Meters: Standard chain link fence installation. Fence posts are fixed below ground level using concrete foundations for stable structural support. Second Section – 300 Meters: Chain link fence installation on an existing concrete wall using an anchoring system. First Part: 40 meters,Second Part: 260 meters.

Anti-Intruder Chain Link Fence Supply (BS 1722-10)

Chain link fence system supplied in accordance with BS 1722 Part 10. All components are hot-dip galvanized steel with green PVC coating for corrosion resistance and anti-intrusion performance. PVC coating on posts and fittings resists peeling, scratching, and damage during transport and installation. All fence components including bracing, tension bands, double clamps, bolts, and posts are supplied as a complete system for secure assembly.

  • Post System: Terminal / corner / straining posts, line / intermediate posts at 3 m center-to-center spacing, post caps for protection.

  • Gate System: 1 set of double-leaf swing gate (8 m width)

  • Accessories: All additional fittings and installation accessories required for complete fence system supply included.

  • Chain Link Mesh System: provides full perimeter coverage and stability.

  • Line and Tension Wire System: 6 rows of line/tension wires along full fence length.

  • Corner Post Tension Bars: 2 stretcher/tension bars per corner or straining post.

  • Horizontal Bracing System: 2 horizontal bracing rods per corner or straining post.

  • Diagonal Bracing System: 2 diagonal bracing rods per corner or straining post.

  • Fixing Accessories System: tension bands, bolts, eye bolts, tie wire for fixing.

  • Barbed Wire Security System: 6 rows of barbed wire along 1.5 km perimeter.

  • Eye Bolt Fixing System: G.I. eye bolts for terminal and corner post fixing.

  • Top Concertina Wire System: 1 row concertina wire installed along fence top line.

  • Ground Concertina Wire System: 3 rows ground concertina wire, 0.65 m diameter.

Security Chain Link Fence Specifications

  • Straining and Corner Posts: 114.3 × 4.5 mm CHS posts to BS 1722 Part 10.

  • Straining Post Material: Steel pipe complies with BS 1387 requirements.

  • Straining Post Coating: Hot-dip galvanized to BS EN 1461 and PVC coated.

  • Straining Post Height: 3.9 m height before installation.

  • Straining Post Base Plate: 200 × 200 × 3 mm welded base plate.

  • Straining Post Top Fittings: Two welded caps per post.

  • Corner Post Y Crank: Y crank for barbed wire direction changes.

  • Line and Intermediate Posts: 60.3 × 3.6 mm CHS posts to BS 1722 Part 10.

  • Line Post Material: Steel pipe complies with BS 1387 requirements.

  • Line Post Coating: Hot-dip galvanized and PVC coated.

  • Line Post Height: 3.8 m height before installation.

  • Line Post Base Plate: 200 × 200 × 3 mm welded base plate.

  • Line Post Top Caps: Two welded caps per post.

  • Chain Link Mesh: 50 mm mesh opening, 2.5 m width.

  • Mesh Wire Diameter: 3.55 mm core wire diameter minimum.

  • Mesh Standard: Plastic-coated zinc wire to BS 4102 Grade A.

  • Line Wire Specification: 3.55 mm galvanized PVC-coated wire.

  • Stirrup Wire Specification: BS 4102 Grade A galvanized wire.

  • Stretcher Bars: 25 × 5 mm galvanized PVC-coated flat bar.

  • Stretcher Bar Accessories: Cleats, eye bolts, and U connectors included.

  • Barbed Wire: 3.0 mm zinc-coated wire to BS 4102.

  • Concertina Wire Diameter: 650 mm outer coil diameter.

  • Concertina Tape Thickness: 0.5 mm razor tape thickness.

  • Concertina Core Wire: 2.5 mm high-tensile core wire.

  • Double Swing Gate: 8 m wide double-leaf swing gate.

  • Gate Material: Steel tubes to BS EN 10210-2.

  • Gate Coating: Hot-dip galvanized and PVC coated.

  • Gate Opening Angle: 180° opening with anti-removal hinges.

  • Gate Locking System: Drop bolts, slam plates, and locking bars.

  • Gate Mesh Infill: Same chain link mesh as fence.

  • Gate Post Specification: 219.1 mm OD × 8.2 mm thick.

  • Gate Frame Specification: 60.3 mm OD × 3.5 mm thick.

  • Gate Bracing Specification: 42.2 mm OD × 3.5 mm thick.

  • Gate Barbed Wire Arms: Vertical arms supporting 3 barbed wire strands.

  • Gate Post Installation: Minimum 750 mm ground embedment depth.

  • Gate Roller Wheels: Adjustable roller wheels with bottom rails.

Wall-Mounted Fence System Specification (300 m)

  • Straining Posts – 3.9 m Height: 114.3 mm straining/corner posts, height 3.9 m for wall section. V-crank included for barbed wire support.

  • Straining Post Fixing Holes – 3.9 m: Each post has 3 holes, 24 mm diameter. Hole spacing 25 cm center-to-center at lower section.

  • Anchor Rod Fixing System: 24 mm holes for threaded anchor rods. All holes aligned on post centerline.

  • Straining Posts – 5.1 m Height: 114.3 mm straining/corner posts, height 5.1 m. Used between standard and wall fence.

  • 5.1 m Post Fixing Holes – 24 mm: Each post has 5 holes, 24 mm diameter. Spacing 0.25 m and 0.60 m. Bottom hole 45 cm from end.

  • Line Posts – 3.8 m Height: 60 mm line posts, height 3.8 m for wall fixing. Designed for anchor rod connection.

  • Line Post Fixing Holes – 20 mm: Each post has 3 holes, 20 mm diameter. Spacing 0.25 m center-to-center. Bottom hole 0.15 m from end.

  • Fence Mesh Extension – 2.8 m Height: Mesh height 2.8 m for wall fixing. Extra 30 cm allows concrete anchoring.

  • 2.8 m Stretcher Bars: 25 × 5 mm galvanized PVC stretcher bars. Includes cleats, eye bolts, U connectors.

  • Diagonal Bracing – 4 m Length: 34.1 × 3.2 mm galvanized steel CHS. PVC coated for wall-to-fence bracing.

  • Bottom Mesh Fixing Bar – 30 mm: 30 × 5 mm stretcher bar, length 2.5 m. With 10 mm fixing holes.

  • Bottom Fixing Hole Layout: Seven 10 mm holes on center line. For 8 mm anchor bolts.

  • Wall Anchor Fixing System: Holes designed for anchor rods. Ensures secure fixing to concrete wall.

Gate and Fence Steel Frame Specification
Gate and Fence Steel Frame Specification

  • A – Chain Link Mesh Filling: 5 cm chain link mesh infill, matching existing fence specification.

  • B – Vertical Frame / Main Post: 219.1 mm OD MS pipe to EN 10210 standard, used for leaf frame and vertical bracing.

  • C – Vertical Frame / Support Pipe: 60 mm OD MS pipe to EN 10210 standard, used for leaf frame vertical bracing.

  • D – Diagonal Bracing Member: 42.2 mm OD MS pipe to EN 10210 standard, used for diagonal frame bracing.

Barbed Wire Tie Hole Positioning (Y Crank)
Barbed Wire Tie Hole Positioning at Y-Crank According to Drawing

Concrete Wall Mounted Chain Link Fence
Chain Link Fence System for Installation on Concrete Walls with Security Posts and Wire Protection

Chain Link Fence
Chain Link Fence Concrete Foundations Installation and Existing Concrete Wall Anchoring System Support

Concrete Wall Chain Link Installation
Chain Link Fence Installation on Existing Concrete Wall Using Anchoring System for Structural Support

Y-Shaped Barbed Wire Bracket
Corner Post Y Crank Arm Chain Link Fence Barbed Wire Support Bracket for Security Fencing

Line post 60 mm dia with 20mm holes
Heavy-Duty 60mm Galvanized Steel Fence Post for Concrete Wall Installation (Fits 16mm Bolts & Barbed Wire)


Comments   Please sign in or sign up to post.

0

0 of 500 characters used

Copyright:@2020-2021