Accu-Tell® Multi-Drug Fast-Dip Rapid Test Panel (Urine)

Author:accubiotech 2020-03-16 12:02:03 394 0 0

Accu-Tell® Multi-Drug Fast-Dip Rapid Test Panel (Urine)

Multi-Drug Urine Test Panel

Accu-Tell® Multi-Drug Fast-Dip Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in human urine at the cut-off concentrations.KEY BENEFIT:

It takes only 1 SECOND to immerse the Fast-Dip test panel in the urine specimen, which saves much more time.

 

CATALOG

Product Name

Specimen

Catalog No.

Quantity per box

Certificate

Multi-2 Drug Fast-Dip Panel 

Urine

ABT-DOA-D282

25T/15T


Multi-3 Drug Fast-Dip Panel

Urine

ABT-DOA-D283

25T/15T


Multi-4 Drug Fast-Dip Panel

Urine

ABT-DOA-D284

25T/15T


Multi-5 Drug Fast-Dip Panel

Urine

ABT-DOA-D285

25T/15T


Multi-6 Drug Fast-Dip Panel

Urine

ABT-DOA-D286

25T/15T


Multi-7 Drug Fast-Dip Panel

Urine

ABT-DOA-D287

25T/15T


Multi-8 Drug Fast-Dip Panel

Urine

ABT-DOA-D288

25T/15T


Multi-9 Drug Fast-Dip Panel

Urine

ABT-DOA-D289

25T/15T


Multi-10 Drug Fast-Dip Panel

Urine

ABT-DOA-D290

25T/15T


 

INTENDED USE

ACCU-TELL® Multi-Drug Fast-Dip Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in human urine at the following cut-off concentrations:

Test

Calibrator

Cut-off (ng/mL)

Amphetamine   (AMP)

d-Amphetamine

1,000/500

Barbiturates   (BAR)

Secobarbital

300/200

Benzodiazepines   (BZO)

Oxazepam

300/200

Buprenorphine   (BUP)

Buprenorphine

10

Cocaine   (COC)

Benzoylecgonine

300/150

Marijuana   (THC)

11-nor-Δ9-THC-9   COOH

50

Methadone   (MTD)

Methadone

300

Methamphetamine   (MET)

d-Methamphetamine

1,000/500

Methylenedioxymethamphetamine(MDMA)

d,l-Methylenedioxymethamphetamine

500

Morphine   (MOP)

Morphine

300

Opiate   (OPI)

Morphine

2,000

Phencyclidine   (PCP)

Phencyclidine

25

Propoxyphene   (PPX)

Propoxyphene

300

Tricyclic   Antidepressants (TCA)

Nortriptyline

1,000

Tramadol   (TML)

Tramadol

100

Ketamine   (KET)

Ketamine

1,000

Oxycodone   (OXY)

Oxycodone

100

2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine   (EDDP)

2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine

300

Synthetic   Marijuana (K2)

JWH-018JWH-073

50

 

Configurations of ACCU-TELL® Drug Metabolites Rapid Test Panel come with any combination of the above listed drug analytes with or without S.V.T. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. For healthcare professionals including professionals at point of care sites.

 

TEST PROCEDURE of Drug Metabolites Rapid Test

Allow the test panel, urine specimen, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.

2. Remove the cap.

3. With the arrows pointing toward the urine specimen, immerse the sample tips vertically in the urine specimen for 1 second. The urine level should be higher than test panel sample injection port. Replace the cap back onto the dip card and place the dip card on a flat surface.

4. The drug strip result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation.

 

LIMITATIONS

1. ACCU-TELL® Multi-Drug Fast-Dip Rapid Test Panel (Urine) provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method.

2. There is a possibility that technical or procedural errors, as well as interfering substances in the urine specimen may cause erroneous results.

3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.

4. A positive result does not indicate level or intoxication, administration route or concentration in urine.

A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.

5. This test does not distinguish between drugs of abuse and certain medications.

6. A positive test result may be obtained from certain foods or food supplements.

 

Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.

TAGS:

Rapid Test Drug Of Abuse



Comments   Please sign in or sign up to post.

0

0 of 500 characters used

Copyright:@2020-2021