Manual of industrial vacuum cleaner

Author:sdfelicitation 2025-01-21 09:47:48 5 0 0

Manual of industrial vacuum cleanerManual of industrial vacuum cleaner

 

YB series industrial vacuum cleaner decomposition view

 

Special notes:

1.After receiving the machine, make sure the device needs voltage! There are instructions for wiring installation

2.When the device automatically tripping protection, open the box to see whether the motor protector overload, such as overload adjustable current increase (as shown in figure) and other reasons to contact customer service.

 

Manual of industrial vacuum cleaner

 

3.Correct checking method when suction of equipment is reduced:

① Check the filter screen for clogging

②Check the suction of the lid suction mouth size (can be analyzed motor problems or filter collection part caused by low suction)

③Check for clogged fittings and hoses

④Check whether the barrel body leak, see the lid joint and (especially the main) under the barrel if the joint leak, check whether the seal tape loose intact. Check if the barrel pulley is loose (figure 1-1) . The upper barrel (filter chamber) can be adjusted downwards (figure 1-2)

 

Manual of industrial vacuum cleaner

 

4.Power line selection method: the general choice of 4-core wire, 3 with power (firewire) a ground wire.

Power line of the choice of 1 square can take 2 kw power such as (7.5 kw machine choice of 4 square power line can be, power line can be particularly long thick)

 

5.The reason and solution of static electricity produced by machine and hose

(1)Check the power cord is installed and whether it is firmly connected to the ground and good contact with the ground (must be connected to the switch with the ground wire and connected to the ground wire, so that the ground wire is connected to the ground)

(2)Check the machine itself whether the ground chain is intact, whether contact with the ground (no or can not contact with the ground in time to add or replace the ground chain, so that the ground chain contact with the ground)

(3)Whether or not the work site is an insulating ground, the insulating ground can not make static electricity export (add a discharge static electricity wire, connected to the nearest place can be derived static electricity)

 

6.The reason why the motor does not work during the operation of the machine is as follows:

(1)Check whether the plug power cord is loose, power is normal (can be measured with a multimeter)

(2)Open the electrical box panel and check that the regulator of the motor protector is in place (5.5 kw 15A, 7.5 kw 17A)

(3)Check whether the AC contactor is working properly (press the button on the AC contactor with an insulating object to see if it can be closed properly)

(4)Press the green button of the AC contactor and use the multimeter to measure whether the three phases of the AC contactor are in the electrified state

(5)Check whether the motor is abnormal:

a. Use a multimeter to measure whether any of the motor's three wires is the same as the motor housing

b. To test whether the motor is running by short-circuit method (avoid AC contactor and connect the power cord with the motor wire directly)

c. With a multimeter test motor three-phase current is consistent, there is a phase is out of phase

(6)With thermal overload relay, press the green button to see if the motor is started, do not start the need to replace the thermal overload relay

 

Safety information: before using the equipment for the first time, please read the equipment instruction manual in detail and use the equipment according to the instruction information during operation.

Logo:In the instructions, follow the instructions below to understand the different meanings of the flags

Manual of industrial vacuum cleaner Danger,Indicating potential hazards, operations such as those marked above may result in serious injury if they are not performed in accordance with the guidelines for use.

Manual of industrial vacuum cleaner Be careful,Show the possible risks that may result in injury if operations such as those marked above are not carried out in accordance with the guidelines for use。

Manual of industrial vacuum cleaner Information,Display important product information or usage suggestions。

 

One.Product introduction:

1.High-pressure turbine fan, non-carbon brush, durable and continuous operation.

2.Equipped with phase-out, overheat and overload power-off protection, effectively protect the motor.

3.High efficiency filter element, precision up to one micron.

4.The dust collecting or material collecting barrel can be separated from the dust collector to facilitate the dust collecting barrel dumping and material recovery.

5.Make the device mobile is very convenient, easy to operate.

6.The utility model has the advantages of compact structure, beautiful appearance, safe use, economy and durability, etc.

 

Two.Main technical parameters and accessories:

Table 1: YB series

Models

Units

YB-401F

YB-551F

YB-751F

Voltage

V/Hz

380/50

380/50

380/50

Power

Kw

4.0

5.5

7.5

Suction

mbar

280

300

320

Wind volume

M³/h

420

530

530

Ash cleaning method

F

F/Manual back blowing

F/Manual back blowing

F/Manual back blowing

Filter area

C㎡

52800

52800

52800

Noise

Db(a)

69

72

72

Diameter of inhalation

Mm

50

50

50

Capacity

L

100

100

100

Weight

kg

120

150

173

Size

Mm

1250*600*1400

 

Environmental considerations:

After unpacking the machine, please do not treat the packing material as household garbage. Please send the packing material to the relevant recycling station for recycling.

 

Standard accessories:

 

Manual of industrial vacuum cleaner

 

Three.YB series Operation Instructions:

1.Make sure the supply voltage is the same as that used by the machine. The operating voltage of the machine is shown in the nameplate parameter table

2.Insert the connecting nozzle at one end of the vacuum hose into the vacuum cleaner (pull up the pull pin to insert into the vacuum port)

 

Manual of industrial vacuum cleaner

 

3.The rubber end of the vacuum hose is inserted with an S-type vacuum tube

 

Manual of industrial vacuum cleaner

 

4.Vacuum grate (pull up the pull pin) inserted into the s-bend

 

Manual of industrial vacuum cleaner

 

5.A flat suction nozzle and a round brush can also be inserted into the rubber joint end of the hose (as shown in the picture)

 

Manual of industrial vacuum cleaner

 

6.Waterproof plug wiring and installation

①Use the screwdriver to press the metal plate and then turn to open the plug (as shown)

 

Manual of industrial vacuum cleaner

 

②Wiring method: L 1, L 2, L 3 connect three fire wires in no particular order, the ground wire mark grounding wire (as shown in figure)

(the ground wire must be linked, do not link will produce static electricity) must check whether the power line ground wire and ground connection!

 

Manual of industrial vacuum cleaner

 

③Plug installation: after connecting the wires, the wire fixing cover is screwed tight and the waterproof plug can be connected to the power supply.

The plug must be inserted to the bottom to prevent poor contact

 

7. Turn the phase sequence switch and press the start button

 

Manual of industrial vacuum cleaner

 

Instructions for using the information:

1.A. B. C. Overload is a lack of phase, non-parallel, overload hint

2.Judge the machine failure according to the prompt

3.Adjustable current regulator 7.5 kw (17-20) a when machine tripping

 

Attention!

Please connect the power supply strictly according to the requirement. The manufacturer will not bear the damage caused by the lack of power supply relative to the motor

 

8.Install dust containers

First off the vacuum motor and power, unplug the vacuum hose, lift the pressure rod pull back to take off the dust bucket, after dumping garbage, installation can be used

 

Manual of industrial vacuum cleaner

 

Attention!Please pay attention to whether the dust collecting bucket is sealed when it is installed.

9.Cleaning: when the filter clogging suction is reduced, must clean the filter, manual back blowing cleaning mode (as shown in figure) :

 

Manual back blowing: Do not stop the state, the vacuum mouth closed, with the hand-pressure back blowing rod several times you can clean dust (aerodynamic principle)

 

Manual of industrial vacuum cleaner

Manual of industrial vacuum cleaner

 

10.Working for a long time filter cleaning does not affect the suction, air gun can be used from the inside out blowing (as shown)

 

Manual of industrial vacuum cleaner

 

Four.Points to note:

1.Pay attention to the influence of working environment on cleaning equipment such as: static electricity, high temperature, vehicles, etc.

2.The power supply, plug and socket shall be used in accordance with state regulations.

3.Beware of electric shock plug when the operator hand must be dry to prevent electric shock。

4.Before using the machine should check whether the dust is suitable for the machine dust, wet dust easily blocked filter dust bag, affect ventilation and filtering effect, not suitable.

5.Beware of electric shock. Please cut off the power supply before cleaning or maintaining the machine.

6.Vacuum cleaner can not be used to absorb flammable and explosive, harmful to human body, corrosive, volatile and radioactive liquid and gas, also can not be used in flammable and explosive dust and gas places.

7.The surface temperature of the inhalant should be ≤60 ° C.

8.Attention to safe transport if the use of locomotives for the transport of equipment, please ensure that the equipment by the fixed belt or fixed pipe fixed to prevent accidental slip.

 

Five.Repair & Maintenance:

The power must be cut off while the machine is being maintained.

*The person in charge shall be obliged to inform the operator of the relevant provisions.

Previous: Conveyor Idlers: The Backbone of Material Handling Systems

Next: Robot Training Equipment: Empowering Precision and Performance

Comments   Please sign in or sign up to post.

0

0 of 500 characters used

Copyright:@2020-2021