Low Temperature Cooling Heating System
Thermal Management Systems For Vehicle/Battery Testing.
The conditioning device is specifically designed for thermal and fluid dynamics test of the liquid-cooled battery pack/battery module.Equipped with high-precision sensors It can test the flow rate, pressure, temperature and sealing of the liquid-cooled battery.
Low Temperature Series (Temperature Control Range -40~85℃,Flow control, Pressure Control)
Cooling power range: 02KW--20KW.
Temperature control range: -40~85℃.
Flow control range:2-20L/min.
Heating power:
Output channel: Output channel: 1,supporting multiple channels.
The control unit of the unit is operated by programmed software. Multiple communication interfaces with protocols are provided for communication with a higher-level automation system.
7 Inch HMI Touched Screen
Display the temperature, flow rate and pressure etc.
Set relevant function.
Check reason for malfunction.
Support data export.
Device Protection
The conditioning unit is protected from damage by safety valves, flow monitors and thermostats and various electrical protection components etc. At the same time,it also has self-diagnosis function and can record the malfunction information. This ensures high reliability and to check the reason of device fault easily in case of a malfunction occurring.
General specifications | ||||||
Model | LQ05K-D | LQ7500-D | LQ10K-D | LQ15K-D | LQ20K-D | |
LQ10k-D-2L | LQ15k-D-2L | LQ20K-D-2L | ||||
LQ20K-D-3L | ||||||
Temp.Range | -20~85℃ | -40~85℃ | -40~120℃ | -40~120℃ | -40~120℃ | |
Temp.control accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Number of fluid output channels | 1 | 1 | 1 | 1 | 1 | |
2 | ||||||
2 | 2 | 3 | ||||
Flow control range per channel | 2~25 L/min | 2~25 Lmin | 2~25L/min | 5~50 L/min | 5~50 L/min | |
Flow control accuracy | ±0.2L | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Heating power | 6kw | 10.5kw | 10.5kw | 10.5kw | 13.5kw | |
cooling capacity | 100℃ | 6kw | 7.5kw | 10kw | 15kw | 20kw |
20℃ | 6kw | 7.5kw | 10kw | 15kw | 20kw | |
Operation display size | 7 inch color touch screen | |||||
Communication | Modbus RTU protocol RS485interface,optional CANcommunication bus,Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function;Refrigerator overload protection;High pressure switch,overload relay,thermal protection | |||||
device,low liquid level protection,high temperature protection,sensor fault protection and other safety functions | ||||||
refrigerant | R404a、R448a、R449a | |||||
Connection size to the test item | ||||||
Cooling water at 20C° | ≤32℃ | ≤32℃ | ≤32℃ | ≤32℃ | ≤32℃ | |
Power 380V50HZ | 20kW | 25kW | 25kW | 30kW | 35kW | |
Dimension cm | 1300*750*1800 | 1300*750*1900 | 1300*750*1900 | 1800*900*1900 | 1800*900*1900 | |
1800*1000*1900 | ||||||
1300*850*1900 | 1800*1000*1900 | 1800*1100*1900 | ||||
Optional | purging function, automatic refill liquid fucntion, cooling power adjustable |