Floor standing gas boiler adopts advanced shell type & three-returns wet-back structure, which consists of boiler body, connecting flue, deaerator pump, deaerator, burner, steam-water system, instruments, economizer, etc. Most prominent feature of the hot water boiler is low nitrogen, the nitrogen oxide emissions is under 30mg/m³ during boiler operation. With the characteristics of compact structure, beautiful outlook, simple operation, safe and reliable operation, floor standing boilers have been widely used in many different industries.
TYPE: | CWNS0.35-0/85/60-Q | CWNS0.7-0/85/60-Q | CWNS1.05-0/85/60-Q | CWNS1.4-0/85/90-YQ |
RATED POWER: | 0.35MW | 0.7MW | 1.05MW | 1.4MW |
RATED HEAT: | 30*10000kcal/h | 60*10000kcal/h | 90*10000kcal/h | 120*10000kcal/h |
PRESSURE: | 0 MPA | 0 MPA | 0 MPA | 0 MPA |
WATER OUT/IN : | 85℃/60℃ | 85℃/60℃ | 85℃/60℃ | 85℃/60℃ |
THERMAL EFFICIENCY : | 93-96% | 93-96% | 93-96% | 93-95% |
CONDENSER EFFICIENCY: | 96-103% | 96-103% | 96-103% | 96-103% |
GAS CONSUPTION : | 40 NM2/H | 70 NM2/H | 110 NM2/H | 140 NM3/H |
WATER OF 50℃ OUTPUT: | 7TON/H | 13TON/H | 20TON/H | 26TON/H |
OUTSIZE: | 2280*1090*1320MM | 2715*1280*1560MM | 2925*1500*1655MM | 3500*2000*2100MM |
USD FOB XINGANG: | 8400 | 12200 | 14700 | 17200 |
Advantages of floor standing gas boilers
• Adopted aluminum silicate fiberboard as heat preservation material, with good heat preservation performance, light weight and convenient transportation and installation
• The front and rear smoke boxes adopt the integral opposite door structure, which is beautiful and elegant, with superior performance, sealed well, and opened easily
during maintenance.
• Adopted original imported burner with high automation. Realized full automatic control of pre-purge, ignition, automatic conversion of fire power, automatic boiler
shutdown and flameout protection.
• Equipped with complete automatic control device and safety protection device, with high and low water level alarm and low water level interlock protection function.
• Boiler automatic ignition, burner fire automatic regulation and flameout protection, to ensure the safe operation of the floor mounted condensing boiler.
• Equipped with manhole device on upper part and inspection device on lower part of free standing gas boilers, easy maintenance.
• Equipped with water level gauge, water level control alarm, pressure gauge, pressure controller and gas and water flow meters, fully meet the monitoring and control
requirements, with first-class safety.
• The application of FGR flue gas recycling technology effectively reduce the content of nitrogen oxides and make the emission of nitrogen oxides below 30mg / m³, which is far lower than the national standard.