Swimming pool heat pumps are highly automated equipment. Regular state inspections are carried out during use. If the heat pump can be maintained and maintained for a long time, its operational reliability and service life will be unexpectedly improved.
Do you know how to maintain the swimming pool heat pump? As a heat pumps supplier, I'd like to share it with you.
On/Off Swimming Pool Heat Pump
1. All the safety protection devices in the swimming pool heat pump have been set before leaving the factory, please do not adjust by yourself.
2. Frequently check the working conditions of the various components of the unit, check whether there is oil contamination in the pipe joints and the inflation valve in the unit, and ensure that there is no leakage of the refrigerant of the unit.
3. Heat pumps should be cleaned at least once a year, and whenever they are dirty or dusty. Dirty air coils can affect equipment performance because they reduce airflow and heat transfer in either direction. Any debris, such as sticks or leaves, from the air inlet of the equipment should be removed to avoid damage to the equipment due to dirty or clogged filters. The area around the heat pump should be dry, clean, and well ventilated to ensure optimal performance.
4. Frequently check the working conditions of the various components of the swimming pool heat pump, and check whether there is oil stains at the pipe joints and inflation valves in the swimming pool heat pump to ensure that there is no leakage of refrigerant.
Frequently check the circulating water pump, whether the water valve is working properly, and whether the water pipes and water pipe joints are leaking.
5. Do not pile up debris around the machine to avoid blocking the air inlet and outlet. The unit should be kept clean, dry and well ventilated.
6. If the swimming pool heat pump stops for a long time, the water in the pipeline of the unit should be discharged, the power supply should be cut off, and the protective cover should be put on. When it is running again, the system should be fully inspected before starting;
7. Frequently check whether the power supply of the swimming pool heat pump and the wiring of the electrical system are firm, whether the electrical components are abnormal, and if any, repair or replace them in time.
Guangteng has the swimming heat pumps of high quality; if you want to learn more about our products, please cotact us.