120W Din Rail Switching Power Supply
MODEL | DR-120-12 | DR-120-24 | DR-120-48 | |
Output | DC Voltage | 12V | 24V | 48V |
Rated current | 10A | 6A | 2.5A | |
Current range | 0-10A | 0-6A | 0-2.5A | |
DC power | 120W | 120W | 120W | |
Voltage ADJ.range | 10.8~13.2V | 21.6~26.4V | 43.2~52.8V | |
Voltage tolerance | ±2% | ±1% | ±1% | |
Ripple and noise | 80mVp-p | 80mVp-p | 100mVp-p | |
Intet stability | ±0.5% | ±0.5% | ±0.5% | |
Load stability | ±1% | ±1% | ±1% | |
Intput | AC voltage range | 90~132VAC/170~264VAC 47~63Hz ; 240~370VDC | ||
Current | 3.3A/115V 2A/230V | |||
Effi ciency | 80% | 84% | 85% | |
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||
Leakage current | < 3.5mA/240VAC | |||
Protection | Overload | 105%~150% Type:pulsing hiccup shutdown Resete:auto recovery | ||
Over voltage | 15~16.5V | 28~33V | 58~65V | |
Safety | Setup,rise,hold up time | 500ms,70ms,50ms/230V | ||
Vibration | 10~500Hz,2G 10min,/1 cycle | |||
Withstand voltage | Input and output internal:1.5KvAc, input and enclosure:1.5KvAc,Output and enclosure:0.5KvAc | |||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||
Environment | ±0.03%/°C (0~50°C ) | |||
Temperature coeffi cient | ||||
Working temperature and humidity | -10°C ~+60°C,20%~90%RH | |||
Store temperature and humidity | -20°C ~+85°C,10%~95%RH | |||
Other | Overall dimension | 65.5×125.2×100mm | ||
Weight | 0.8Kg | |||
Certificate | CE EMC Authenticate | EN55022:2010 EN61000-3-2:2006+AL:2009 EN61000-3-3:2008 | ||
EN55024:2010 EN55015:2006+AL2007+2009 EN61547:2009 |
Contact us for more information.