MODEL | MS-60-5 | MS-60-12 | MS-60-24 | MS-60-48 | |
OUTPUT | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 12A | 5A | 2.5A | 1.25A | |
Current range | 0 ~ 12A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |
Rated power | 60W | 60W | 60W | 60W | |
Ripple & noise | 100mVp-p | 120mVp-p | 200mVp-p | 240mVp-p | |
Voltage ADJ. range | ±10% | ±10% | ±10% | ±10% | |
Setup,rise,hold time | 800ms, 30ms, 20ms/230VAC | ||||
INPUT | Voltage range | 85~264VAC 230~370VDC | |||
Frequency range | 47 ~ 63Hz | ||||
Efficiency | 78% | 80% | 83% | 84% | |
Ac current | 1.2A/115VAC 0.6A/230VAC | ||||
Inrush current | Cold start 45A | ||||
Leakage current | <2mA/240VAC | ||||
PROTECTION | Overload | 115 ~ 150% rated output power | |||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
Over voltage | 5.8~6.8V | 14~16.5V | 28~32V | 55~64V | |
Protection type :Shut off | |||||
ENVIRONMENT | Working temp,humidity | -10℃ ~ +60℃,20% ~ 90% RH non-condensing | |||
Storage temp,humidity | -20℃ ~ +80℃,10% ~ 95% RH non-condensing | ||||
Withstand vibration | 10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes | ||||
SAFETY & EMC | Safety standard | Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved | |||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMC standard | EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved | ||||
OTHERS | MTBF | 400K hrs | |||
Dimension | 110*78*36mm (L*W*H) | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |