There are generally two types of wastewater flush valves: one is replaced by a wastewater ratio, and the other is a solenoid valve with a self-washing delay of 18 seconds with a wastewater ratio (or non-self-flushing solenoid valve with wastewater ratio -- only for pure water machine with computer version). The role of course is to adjust the inlet pressure of the reverse osmosis membrane to achieve the purpose of water production.
A brief analysis of the function of the wastewater flushing valve of the pure water machine
Reverse osmosis is to add a higher pressure than the natural osmotic pressure to the concentrated liquid to reverse the direction of natural osmosis. The solvent (water) in the concentrated solution is pressed into the dilute solution on the other side of the semipermeable membrane. This is the opposite of the normal osmosis process in nature, so it is called reverse osmosis. The reverse osmosis membrane can remove charged ions, organic matter, colloids, bacteria, particles, inorganic matter, etc. in the water. The desalination effect of the reverse osmosis system is the most cost-effective in the desalination equipment.
Two conditions must be met for reverse osmosis operation. First, there must be a semi-permeable membrane with high selectivity and high water permeability. The reverse osmosis membrane selected by our company is an imported roll-type composite membrane, which has the characteristics of large water flow and high recovery rate;
Another condition is that the operating pressure must be higher than the osmotic pressure of the solution, that is, an appropriate high-pressure pump is selected. The high-pressure pump has the characteristics of stable operation, low noise, low energy consumption, and continuous operation. The reverse osmosis system adopts PLC automatic control, which has the characteristics of simple operation and low operating cost. The scope of application of reverse osmosis technology is extremely wide, and it has become a piece of the necessary equipment in projects such as pure water, high purity water, seawater desalination, and brackish water desalination.
Analysis of the effect of the wastewater flush valve of the pure water machine:
There are generally two types of wastewater flushing valves: one is replaced by wastewater ratio, and the other is a solenoid valve with a self-washing delay of 18 seconds with a wastewater ratio (or non-self-flushing solenoid valve with wastewater ratio -- only for pure water machine with computer version). The role of course is to adjust the inlet pressure of the reverse osmosis membrane to achieve the purpose of water production.
The information is provided by flush valve supplier.
Copyright:@2020-2021
Comments Please sign in or sign up to post.
0
0 of 500 characters used