1. To change the rubber type, the pipeline needs to be cleaned. At this time, first close the feed valve, open the discharge valve, and discharge the remaining rubber in the plastic bucket. Close the discharge valve and open the feed valve to pour the cleaning solvent into the plastic storage bucket, activate the body, and use the normal operation Squeeze out.
2. The air pressure intake is abnormal and water vapor is found. Please sweep the water vapor in the pressure regulating filter or check whether the air pressure source is abnormal. Before using Glue Dispensing Machine in large quantities, please try it out in small quantities and grasp the application skills of the product to avoid mistakes. When the test is no problem, use a two-drop glue dispenser or a two-fill glue dispenser for mass production; The vacuum system performs vacuum defoaming treatment on the glue to remove the bubbles that occur during the mixing process, or let it stand for 10-20 minutes before use so that the bubbles that occur during mixing are removed in time, and the more glue is mixed together.
3. Please wipe the machine part regularly to increase the service life. The more the amount of glue mixed together, the faster the reaction and the faster the curing speed, so the glue should be reasonably formulated according to the actual production situation, otherwise the glue will be wasted. Eliminate accidents and improve production efficiency. Now liquid control skills and dispensing equipment are widely used in various production fields in modern industry.
4. Unplug the power supply when the machine is not used for a long time. This will not only extend the life of the machine but also save a lot of electricity costs. With the needs of the rapid development of industry, liquid control skills and dispenser equipment are also continuously developed to ultra-high precision control and diversification and specialization.
Standalone Dispensing Machine
How to solve the problem that the Automatic Glue Dispensing Machine does not reset?
It is well known that the motor is small and exquisite, stable operation and low price. It is a machine that can restore the automatic dispenser equipment to the set state after it is turned on. It is widely used in the industrial control industry. Of course, it does not mean that it will not cause problems if it is stable. Generally speaking, there is no reset phenomenon when the dispenser is turned on, which indicates that the motor has failed.
First check the question of the emergency stop button of the automatic dispenser to see if it is pressed. There may be a problem with the wiring of the automatic dispenser. At this time, open the case, check whether the hardware of the automatic dispenser is connected correctly, and whether the driver is powered on. After confirming that they are correct, then the firmware or configuration file of the automatic dispenser is incorrect It is because the firmware of the automatic dispenser has not been successfully upgraded, or the configuration file has not been successfully updated. At this time, you need to upgrade the firmware.