Brass Terminal Bar with Fixing Part GK001-0609
Terminal series use high quality brass raw material,has the characteristics of high-current- carrying capacity, convenient-wiring and durable quality.With acid-pickling treatment, products are not easily oxidized.Due to Precisely manufacturing, it avoid the difficulty of reinstallation after many times .
Pole No. | Installation Dimension(mm) | Outline Dimension(mm) | Sectioncross of Brass(mm2) |
4 | 48.2 | 59.2*11.2 | 6*9 |
6 | 65.4 | 76.4*11.2 | 6*9 |
8 | 82.6 | 93.6*11.2 | 6*9 |
10 | 99.8 | 110.8*11.2 | 6*9 |
12 | 117 | 128*11.2 | 6*9 |
Requirements to a Brass Terminal body
1 The terminal body is manufactured from copper-zinc alloy
2 The terminal body is to be manufactured in parallelepipedal shape with mutually perpendicular side planes. Deviation of perpendicularity is no less than 0,1mm
3 The other sharp edges are to be blunted
4 The surface of holes for wire mounting is to be smooth without burrs, edge fins and etc.
5 The form of thread into threaded openings is to be full without edge fins. Every opening is to have no less than three full turns of a thread
We are Power Distribution Block Supplier.
Requirements to a terminal
1 The terminal is to be equipped with screws in the quantity equal to the quantity of contact groups for the wire fixing
2 The screws are not to create troubles to next screws at the operation
3 Dimensions and completed set of terminals are to correspond to design documents.
4 Operation temperature range could be from minus 40 to plus 50 °С.
Outgoing inspection of High-Quality Brass Terminal
Visual Check:
Bring out the absence of outer damages, deep scratches, cracks, chips, corrosion on the terminals and screws.
All screws are to be entirely tightened.
Temperature Rise Test :
5% of the batch of each standard size, but not less than 10 pcs.
Flame Retardant Test:
5% of the batch of each standard size, but not less than 10 pcs.
Certifications:
CE, can be of ROHS at your decision
More information please click here.
Previous: FEATURES AND ADVANTAGES OF LED PLANT LIGHTS
Next: Do you know the performance selection of RF Coaxial Connectors?
Copyright:@2020-2021
Comments Please sign in or sign up to post.
0
0 of 500 characters used